China Organic Heat Carrier Heater Thermal Oil Boiler for Synthetic Fiber Industry
Basic Info
Model NO. | 500kw 700kw |
Function | Oil Boiler |
Fuel | Oil-Fired |
Installation | Assembled Boiler |
Structure | Hot Oil Tube |
Media | Organic Heat Transfer Material |
Water Circulation | Natural Circulation |
Drum Placement | Horizontal Boiler |
Pressure | Low Pressure |
Manufacturing Level | A |
Burning Style | Chamber Combustion Boiler |
Usage | Industrial |
Product | Thermal Oil Boiler Heater |
Boiler Fuel | Natural Gas, Diesel, Heavy Oil, Light Oil |
Medium | Organic Heat Transfer Material |
Thermal Capaicty | 30,000 Kcal/Hr to 2,000,000 Kcal/Hr |
Highest Work Temperature | 320c |
Application | Chemical, Chemical Fiber, Pharmaceutical |
Design Pressure | 0.8MPa |
Work Pressure | 0.6MPa |
Thermal Efficiency | 85% |
Warranty | 1 Year |
Transport Package | Wooden Package |
Specification | 120-20000KW |
Trademark | Jinzhen Boiler |
Origin | Henan, China |
HS Code | 8404101000 |
Production Capacity | 50 Set/Month |
Product Description
China Organic Heat Carrier Heater Thermal Oil Boiler For Synthetic Fiber IndustryProduct Descriptionthermic Fluid Heater, thermal oil boiler, hot oil boilerRated thermal power is 0.12Mw (10×104kcal/h) to 14Mw (1200×104kcal/h).Design pressure is equal to or greater than 1 Mpa.Operating temperature is equal to or less than 350°C.Thermal efficiency is between 60% and 85% according to the difference of boiler type.Available fuel:natural gas, coke oven gas, bio-gas,liquefied petroleum gas, diesel, heavy oil, light oil, crude oilAvailable industries:Petroleum, chemical, chemical fiber, pharmaceutical, textile printing and dyeing, building materials, wood processing, vegetable oil processing and other industriesHeat Transfer Fluid heaters (hot oil heater) to oil (gas) as fuel to oil as medium, using hot oil circulation pumps mandatory medium for liquid circulation, the energy delivery device and then return to Heat re-heating furnace with low pressure in the working temperature was high, and can run on medium high-precision control. System with high thermal efficiency, due to the overall module installation, operation and easy maintenance, is a safe, efficient, energy saving ideal choice for heating equipment. Working Principle Of Thermic Fluid Heater
Fuel oil (gas) from the burner flame after ignition temperature generated within the coil to form into the radiation heating surface, through the internal coil rotated by 180 °into the rear forward, the foreign control of the mezzanine area convection heating surface. Then enter the upper mezzanine, the outer coil of the second mezzanine area, in the second mezzanine area to the rear of the chimney into the atmosphere.
Work Principle Of Thermal Oil Boiler Fuel oil (gas) from the burner flame after ignition temperature generated within the coil to form into the radiation heating surface, through the internal coil rotated by 180 °into the rear forward, the foreign control of the mezzanine area convection heating surface. Then enter the upper mezzanine, the outer coil of the second mezzanine area, in the second mezzanine area to the rear of the chimney into the atmosphere.This thermic fluid heater has advanced program control system, equipped with liquid level controller , pressure controller, temperature controller, and alarms to make sure the boiler work orderly and safe. So it is a kind of safe boiler with high efficiency and low power consumption.
Its advantage is Free-Installation
All thermal oil boilers are assembly structure which is easy for installation by just connecting system device by pipes. Intelligent system control of thermal oil fluid haters makes boiler operation easier and more simple. Controller with imitation screen display has auto igniting, burning, circulation pumps control, alarm, etc. functions
Model No. | Thermal power(kcal/h) | Heating efficiency (%) | Max. working temp.(ºC) | Medium circulation(M3/H) | Transport size (mm) | Weight (Kg) |
YY(Q)W-120Y(Q) | 10*104 | ≥92.26 | 340 | 12.5 | Φ1060*2045 | 1215 |
YY(Q)W-240Y(Q) | 20*104 | ≥92.26 | 340 | 18 | Φ1020*1980 | 1355 |
YY(Q)W-350Y(Q) | 30*104 | ≥92.26 | 340 | 30 | Φ1212*2310 | 1590 |
YY(Q)W-500Y(Q) | 40*104 | ≥92.26 | 340 | 30 | Φ1212*2730 | 1680 |
YY(Q)W-700Y(Q) | 60*104 | ≥92.26 | 340 | 60 | Φ1400*3410 | 2715 |
YY(Q)W-900Y(Q) | 80*104 | ≥92.26 | 340 | 80 | Φ1616*3400 | 3142 |
YY(Q)W-1200Y(Q) | 100*104 | ≥92.26 | 340 | 100 | Φ1616*4000 | 3660 |
YY(Q)W-1400Y(Q) | 120*104 | ≥92.26 | 340 | 100 | Φ1820*4905 | 5420 |
YY(Q)W-2000Y(Q) | 160*104 | ≥92.26 | 340 | 100 | Φ1840*4950 | 7850 |
YY(Q)W-2400Y(Q) | 200*104 | ≥92.26 | 340 | 160 | Φ2060*4700 | 8850 |
YY(Q)W-3000Y(Q) | 250*104 | ≥92.26 | 340 | 180 | Φ2060*5450 | 9210 |
YY(Q)W-3500Y(Q) | 300*104 | ≥92.26 | 340 | 200 | Φ2430*5965 | 9960 |
YY(Q)W-4100Y(Q) | 350*104 | ≥92.26 | 340 | 250 | Φ2630*6990 | 1120 |
YY(Q)W-4700Y(Q) | 400*104 | ≥92.26 | 340 | 250 | Φ2830*7100 | 1230 |
1. The top of the thermal boiler(hot oil boiler) is equipped with a top coil tube, which effectively prevents the flame from directly radiating the rear wall. At the same time, under the premise of a compact structure, it increases the radiation heating area and improves the boiler's thermal efficiency.2. The use of micro positive pressure operation effectively improves the combustion intensity of the furnace, makes the volume of the boiler with the same capacity smaller, and eliminates the air leakage of the furnace and flue of the boiler, and improves the thermal efficiency of the boiler.3. Using advanced EDA technology, detailed calculation of furnace body size, flue gas flow rate, reasonable and full use of flame and flue gas heat exchange to ensure reliable operation and sufficient cooling of the boiler, and improve the boiler's thermal efficiency.4. The use of high-efficiency condensation technology effectively reduces the temperature of exhaust gas and improves the thermal efficiency of the boiler.5. Adopt reasonable structure design and excellent refractory and heat insulation materials, greatly reduce the surface temperature of the furnace body, make the surface temperature lower than 50 degrees (higher than the national standard), reduce heat loss, and improve the thermal efficiency of the boiler.6.Adopt a new design to reduce the emission of harmful substances during fuel combustion, meet the national environmental protection standards, especially reduce the emission of nitrogen oxides, and meet the national low nitrogen emission standards.The Gas/Oil Fired thermal oil boiler auxiliaries
Name | Quantity(unit/piece) |
main body of thermal oil boiler | 1 |
Oil Circulating pump | 1 |
Gas/oil burner | 1 |
oil filling pump | 1 |
Filter | 1 |
Electric control cabinet | 1 |
high level oil storage tank | 1 |
Low level oil storage tank | 1 |
Valves and gauges | one batch for whole system |
Application of thermal oil boiler | |
Chemical: | polymerization, condensation, distillation, concentration, evaporation, fusion |
Fat: | decomposition, deodorization, distillation of aliphatic acid, heating, hydrogenation,esterification. |
Petrochemical: | rectification, heating, thermal insulation |
Plastic&Rubber: | hot-press, calender, extrusion, vulcanization molding, artical leather manufacture |
Textile staining: | heat setting, dry, curing |
Fiber: | polymerization, fusion, mould pressing, thermosetting, extension, dry |
Carbon: | bitumen fusion, dripping, mixing,molding |
Wood: | veneer, MDPE,HDPE,lamination flooring,birch hot-pressing, drying |
Metal: | pickling, electroplate, coating, oil bath, heat-treatmen |
Coating: | basting and drying, vehicle, plane, hot forming, hyperthermia bonding, drying |
Construction: | highway hitumen, dissolving, thermal insulation |
Cement: | fuel heating |
Electric: | resin impregnation, melting&holding |
Air-condition: | radiant heating |
Others: | different application of high temperature heat source below 350°C. |
FAQ of thermal oil boiler1.What is the highest temperature that thermal oil heater could achieve?thermal oil heater can reach as high as 330ºC, and working under low pressure (<1.0MPa)2.What are the heat-resistance temperature of grate and furnace?The heat resistance temperature of grate is related to the grate material, the highest temperature could be as high as 1100ºC, and the lower temperature could be 700ºC.The highest heat resistance temperature of furnace could be about 1700ºC~1800ºC.3.What is conduction oil/ hot oil / heat transfer fluid?Conduction oil has a high boiling point, it usually used for the industries that need the temperature of 150~350ºC, to instead of steam. The hot oil has the advantages of high transfer efficiency, fast heat transfer, and good thermal stability.